Chapter 5 · Mini PWZ II

Communication Interfaces

You can change the parameters via the WebServer (recommended) or with the IRS.DiscoveryTool (available from the IRS download area). The procedure is described in the chapter Initial Commissioning.

5.1Factory Settings

If you press the Factory settings button for longer than 4 seconds (until the red LED lights up), the default settings are restored.

5.2Ethernet

Default settings

  • IP address: 192.168.222.1
  • Subnet mask: 255.255.255.0
  • Gateway: 0.0.0.0

5.3FD CAN

Default settings

Frame format

The module supports Classic CAN and FDCAN.

Database

You can download a database file (SYM or DBC) that describes all commands from the IRS download area.

myIRS – Downloads

5.3.1Identifier Structure

Only extended identifiers are used.

BitsContent
28Direction (0 for uC RX, 1 for uC TX)
27-20Command (RX) / status (TX)
19-12Module ID (P for PASw)
11-0User-defined addressing