5.1Type label

5.2General data
| Item | Variant | Value | Unit |
|---|---|---|---|
| EME 1x 3-phase (W x D x H) | 1x VARIS II | 800 x 900 x 2050 | mm |
| EME 2x 3-phase (W x D x H) | 2x VARIS III | 1200 x 900 x 2050 | mm |
| Weight approx. | 1x VARIS II / 2x VARIS III | 500 / 800 | kg |
5.3Operating conditions
| Item | Value | Unit |
|---|---|---|
| Temperature range | 5-35 | °C |
| Relative humidity | max 31 °C: 80 | % |
| Relative humidity | max 40 °C: 50 | % |
| Relative humidity | No condensation | |
| Setup | in dry laboratory rooms | |
| altitude above sea level | max. 2000 | m |
5.4Supply connections
| Tester component | Item | Value | Unit |
|---|---|---|---|
| AC Input | Supply voltage | 100…240 | VAC |
| AC Input | Supply frequency | 50/60 | |
| Tester electronics supply | Max. Current | 6 | AAC |
| Tester electronics supply | Max. Current | Typ. 0,5 | kVA |
| DC-Supply | DC supply voltage | 0…1000 | VDC |
| DC-Supply | DC supply current (Depending on use-case) | -150…150 | AAC |