Features

  • Discharging DC-link circuits up to 1500 V
  • Discharge current up to 15 A (at 100 Ω, 1500 V)
  • Designed for DC-link capacitances up to 10 mF
  • Two independent, electrically isolated channels, usable individually or in a redundant configuration
  • Solid-state switches instead of relays: long service life, no contact wear, no sticking, no arcing
  • Fail-safe: Discharge in the event of a line break, control failure, or failure of the 24 V power supply
  • Potential-free interlock contacts per channel (normally open and normally closed)
  • Status signal per channel confirming that a discharge current has flowed
  • No cooling required
  • Standard version for 100 Ω discharge resistor; other variants available upon request
  • Compact design; mounting on TS35 top-hat rail
Top View
Figure 1: Top View