Chapter 3
Technical Data
3.1Power Supply and Control
| Parameter | Value |
|---|---|
| Supply | 24 V DC |
| Power consumption | 1 W |
| Controll In±x | 24 V |
| Input current In±x | ca. 6 mA bei 24 V |
| Status | 24 V related to GND |
| Turn on delay → Discharge | 580 ms |
3.2Discharge Circuit (per Channel)
| Parameter | Value |
|---|---|
| Discharge voltage | max. 1500 V DC |
| Max. DC-link capacitance | 10 mF (bei 100 Ω) |
| Discharge Resistor (external) | Standard 100 Ω, weitere Varianten auf Anfrage |
| Status signal threshold | 0,6 A (entspricht 60 V bei 100 Ω) |
| Quiescent current from the DC-link (Discharge OFF) | <1 mA bei 1500 V |
3.3Interlock Contacts (per Channel)
| Parameter | Value |
|---|---|
| Configuration | 1 Normally closed (NC) and 1 normally open (NO), potential-free, solid-state relay |
| Max. switching voltage | 32 V AC/DC |
3.4Insulation and Environmental Conditions
| Parameter | |
|---|---|
| Insulation voltage, control side / high-voltage side | |
| Insulation voltage, channel 1 / channel 2 | |
| Overvoltage category | II |
| Pollution degree | 2 |
| Degree of protection | IP20 |
| Operating temperature | |
| Storage temperature | |
| Relative humidity |
3.5Mechanical Specifications
| Parameter | Value |
|---|---|
| Dimensions (B × H × T) | 90 × 63 × 72 mm |
| Weight | 140 g |
| Mounting | Hutschiene TS35 (EN 60715) |
| Connection (high-voltage side) | Snap-in-Connector, pitch 7,5 mm (Weidmüller TERM BLOCK PLUG 2 POS 7.50), 0.5-4 mm² |
| Connection (control side) | Push-in-Connector, pitch 3,5 mm (Weidmüller BL/SL 3.50), 0.14-1.5 mm² |
3.6Standards and Approvals
| Parameter | Value |
|---|---|
| Compliance | RoHS |
¹ The peak current depends on the discharge resistor and is calculated as Imax = UDC / R. For a 100 Ω discharge resistor at 1500 V DC, the peak current is 15 A.