The current measurement module CMM-IV can be used to measure, evaluate and check current consumption of a dynamic DC load, typically an automotive electronic control unit. It can measure currents from 1µA to 100ADC (190A range) with automatic range selection that switches within microseconds. The current range from 1µA to 190A is split into 7 ranges, i.e. seven decades.
| Range | Nominal Range min | Nominal Range max | Lower Range is selected at | Higher Range is selected at |
|---|---|---|---|---|
| 0 | 1 µA | 100 µA | - | 110 µA |
| 1 | 100 µA | 1 mA | 90 µA | 1.1 mA |
| 2 | 1 mA | 10 mA | 0.9 mA | 11 mA |
| 3 | 10 mA | 100 mA | 9 mA | 110 mA |
| 4 | 100 mA | 1 A | 90 mA | 1.1 A |
| 5 | 1 A | 10 A | 0.9 A | 11 A |
| 6 | 10 A | 190 A | 9 A | - |
Intended use
This module is designed to be used as a current measurement device in an industrial environment. It is not designed to be used as a power switch.
Purpose of this document
The purpose of this document is to describe how to integrate the module in a test system and how to access it from the software point of view. Limits of application are shown in the technical data section.
This document is addressed to system integrators and the users, who are applying the module.
Document overview
This document contains 3 sections.
- The first section includes an introduction to this manual
- The second section includes description of the hardware
- The third section includes accessing the module from the software point of view.
Documents and downloads
Further documents and files for your IRS product are available on myIRS.