Kapitel 1.1.2.2.3 · LTT

TS Module

Diese Seite gibt es noch nicht auf Deutsch, daher wird die englische Fassung angezeigt.

A temperature sensor (TS) module has the following mandatory standard parameters:

ParameterMeaningExamples
ResourceThe connection information needed to connect to this device. Depending on the type of device this can be a COM port, a GPIB address, an IP address or something else. Most drivers are based on VISA, which brings its own syntax to provide a GPIB or IP address. The VISA resource names can usually be looked up in NI Max.

COM1
GPIB0::1::INSTR
TCPIP::192.168.222.50::INSTR

MinTempThe lower temperature limit in °C. This value can be changed through the LTT GUI. The GUI will stop all running tests if this limit will be violated.-41
MaxTempThe upper temperature limit in °C. This value can be changed through the LTT GUI. The GUI will stop all running tests if this limit will be violated.120

Depending on the specific TS module, there might be additional parameters, which are described here.

You can access the TS control panel through GUI and also via TestStand..

Kapitel 1.1.2.2.3.1

Driver Specific Parameters

Some temperature sensor drivers have additional parameters besides the standard ones described in here.

1.1.2.2.3.1.1PMA280

ParameterMeaningExamples
Baud RateAn optional parameter providing the baud rate for the PMA280 module. If not provided 9600 is the default baud rate.9600
19200
Timeout [ms]An optional parameter specifying the communication timeout for the PMA280 module. There are cases where you need to increase the default communication timeout, otherwise it will lead to sporadic timeout errors. If you connect via Windows Remote Desktop it is recommended to set a timeout value of 3000.1000
2000
3000