# TS Module

URL: https://irs.systems/en/docs/ltt/documentation/ltt-gui-manual/configuration/moduleconfiguration/ts

A temperature sensor (TS) module has the following mandatory standard parameters:

| Parameter | Meaning                                                                                                                                                                                                                                                                                                                        | Examples                                                       |
| --------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | -------------------------------------------------------------- |
| Resource  | The connection information needed to connect to this device. Depending on the type of device this can be a COM port, a GPIB address, an IP address or something else. Most drivers are based on VISA, which brings its own syntax to provide a GPIB or IP address. The VISA resource names can usually be looked up in NI Max. | <p>COM1<br>GPIB0::1::INSTR<br>TCPIP::192.168.222.50::INSTR</p> |
| MinTemp   | The lower temperature limit in °C. This value can be changed through the [LTT GUI](../../../LTTGUI/Dialogs/F10testparameterconfiguration/). The GUI will stop all running tests if this limit will be violated.                                                                                                                | -41                                                            |
| MaxTemp   | The upper temperature limit in °C. This value can be changed through the [LTT GUI](../../../LTTGUI/Dialogs/F10testparameterconfiguration/). The GUI will stop all running tests if this limit will be violated.                                                                                                                | 120                                                            |

Depending on the specific TS module, there might be additional parameters, which are described [here](../../../LTTGUI/Dialogs/F10testparameterconfiguration/).

> You can access the TS control panel through [GUI](/en/docs/ltt/documentation/ltt-gui-manual/lttgui/hwcontrol/ts-control-gui) and also via [TestStand](/en/docs/ltt/documentation/ltt-gui-manual/teststand/hardware-control)..