# Driver Specific Parameters

URL: https://irs.systems/en/docs/ltt/documentation/ltt-gui-manual/configuration/moduleconfiguration/ps/ps-parameters

Some power supply drivers have additional parameters besides the standard ones described in [here](/en/docs/ltt/documentation/ltt-gui-manual/configuration/moduleconfiguration/ps).

## Delta.PSC232

| Parameter | Meaning | Examples |
|-----------|---------|----------|
| Address | This parameter is mandatory. It specifies the internal device address (not to be confused with the COM port). | 1<br>4<br>6 |
| Baud Rate | This parameter is mandatory. It specifies the baud rate for the communication. | 9600<br>19200 |

## EA.PSI800R

| Parameter | Meaning | Examples |
|-----------|---------|----------|

## Model

| Parameter | Meaning | Examples |
|-----------|---------|----------|
| Model | This parameter is mandatory. It specifies the Model of the Power Supply. | PSI800R<br>PS80002U_3U |

## Keysight.E363X

| Parameter | Meaning | Examples |
|-----------|---------|----------|
| Data Bits | This parameter is mandatory. It specifies the Data bits. | 8<br>7 |
| Parity | This parameter is mandatory. It specifies the Parity bit. | odd<br>even<br>mark |
| Flow | This parameter is mandatory. It specifies the Serial Flow Control. | xon/xoff<br>dtr/dsr |
| Baud Rate | This parameter is mandatory. It specifies the baud rate for the communication. | 9600<br>19200 |

## Kniel

| Parameter | Meaning | Examples |
|-----------|---------|----------|

## Kniel.New

| Parameter | Meaning | Examples |
|-----------|---------|----------|
| Node | This parameter is optional. It specifies the internal device address (not to be confused with the COM port). | 1 |
| Baud Rate | This parameter is mandatory. It specifies the baud rate for the communication. | 9600<br>19200 |

## Sim

| Parameter | Meaning | Examples |
|-----------|---------|----------|
| SimulateInitError | This parameter is optional. It specifies if a Error should occur while initialization | True<br>False |

## TDK.Gensys

| Parameter | Meaning | Examples |
|-----------|---------|----------|
| Address | This parameter is mandatory if the PS is connected via a COM port. It specifies the internal device address (not to be confused with the COM port). | 1<br>4<br>6 |
| Baud Rate | This parameter is mandatory if the PS is connected via a COM port. It specifies the baud rate for the communication. | 9600<br>19200 |

## TDK.GensysPlus

| Parameter | Meaning | Examples |
|-----------|---------|----------|
| Address | This parameter is mandatory if the PS is connected via a COM port. It specifies the internal device address (not to be confused with the COM port). | 1<br>3<br>6 |
| Baud Rate | This parameter is mandatory if the PS is connected via a COM port. It specifies the baud rate for the communication. | 9600<br>19200 |

## TDK.LambdaZ

| Parameter | Meaning | Examples |
|-----------|---------|----------|
| Address | This parameter is mandatory if the PS is connected via a COM port. It specifies the internal device address (not to be confused with the COM port). | 1<br>3<br>6 |
| Baud Rate | This parameter is mandatory if the PS is connected via a COM port. It specifies the baud rate for the communication. | 9600<br>19200 |